Telephone +44 (0) 1342 330 470

Monday to Thursday: 08.30 to 17.00 (GMT)
Friday: 08.30 to 12.45 (GMT)

Catalog Advanced Search

14 item(s) were found using the following search criteria

  • Manufacturer: Process Parameters Ltd

Don't see what you're looking for? Modify your search

14 Item(s)

per page

Set Descending Direction
  1. Compact temperature transmitter RPL23-TX

    Compact temperature transmitter RPL23-TX

    The lagging extension allows the sensor to operate at temperatures up to 250°C. UKAS or traceable calibration is available upon request..

    • -50°C to +250°C
    • 4-20mA, 2 wire
    • 10-30V d.c. loop powered
    • Class 1 or Class 2 tolerance band
    More Info
  2. Mineral insulated Pt100 with terminal head RPL15-P

    Mineral insulated Pt100 with terminal head RPL15-P

    A choice of terminal heads is available to be fitted to the sensor in either a terminal block or transmitter can be fitted. UKAS or traceable calibration is available

    • -50°C to 500°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  3. PPL1-P RTD probe assembly

    PPL1-P RTD probe assembly

    The PPL1-P RTD probe sensor series is designed for a wide range of general purpose industrial applications that require a flying lead Pt resistance sensor. The unit is ideal for use with compression fittings or the PPL50-TW pocket. UKAS traceable calibration is available upon request. 

    • -50°C to +250°C operating temperature range
    • Stocked in 2 Class A 3-wire PT100 sensor variations
    • UKAS traceable calibration available upon request
    • Can be used with compression fittings or pockets
    More Info
  4. PPL2-P RTD probe assembly with thread

    PPL2-P RTD probe assembly with thread

    The PPL2-P platinum probe sensor is designed for a wide range of general purpose industrial applications that require a flying lead sensor with a built in process connection. This device has a welded process connection to simplify installation meaning there is no need for compression fittings. UKAS traceable calibration is available upon request.

    • -50°C to +250°C operating temperature range
    • Stocked in 2 Class A 3-wire PT100 sensor variations
    • UKAS traceable calibration
    • No need for compression fittings
    More Info
  5. PPL3-P RTD probe with terminal head

    PPL3-P RTD probe with terminal head

    The PPL3-P platinum probe sensor with terminal head is available in various combinations and options including sensor type, head types and number of wires. These RTD probe sensors are available with up to IP68 environmental protection (KNE and KSE aluminium alloys and 316 stainless steel). 

    • -50°C to +250°C operating temperature range
    • Pt100 or Pt1000 sensor types available
    • Heads available in Aluminium, Stainless Steel, Nylon or ABS
    • Up to IP68 environmental protection
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class B, Class A, 1/3 Din, 1/5 Din or 1/10 DIN tolerance bands available.
    More Info
  6. RTD compact temperature transmitter  RPL22-TX

    RTD compact temperature transmitter RPL22-TX

    Two connector options are available offering either IP65 or IP67 environmental protection. Various common options are shown on this data sheet but this is not an exhaustive list, please contact us with your requirements. UKAS or traceable calibration is also available.

    • -50°C to 250°C operating temperature range
    • 10-30V d.c. loop powered
    • 4-20mA, 2 wire
    • UKAS traceable calibration
    More Info
  7. RTD compact temperature transmitter with plain stem RPL20-TX

    RTD compact temperature transmitter with plain stem RPL20-TX

    Two connector options are available offering either IP65 or IP67 environmental protection. Various common options are shown on this data sheet but this is not an exhaustive list, please contact us with your requirements. UKAS or traceable calibration is also available.

    • -50°C to 250°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  8. RTD mineral insulated with lead RPL13-P

    RTD mineral insulated with lead RPL13-P

    The sensor can also be made in almost any length that may be required. Various common options are shown on this data sheet but this is not an exhaustive list, please contact us with your requirements. UKAS or traceable calibration is available upon request.

    • -50°C to 500°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  9. RTD probe  with pocket and insert RPL8-P

    RTD probe with pocket and insert RPL8-P

    We can manufacture the sensor stem in any immersion length and process connection to meet your exact requirements. A lagging extension can also be specified and with various options available for the terminal head, including IP68 stainless steel versions, we are sure to satisfy all of your requirements.

    • -50°C to 250°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  10. RTD probe with hygienic process connection  RPL6H-P

    RTD probe with hygienic process connection RPL6H-P

    The sensor stem can be manufactured in various diameters and lengths to meet your exact requirements and with various options available for the terminal head, including IP68 stainless steel versions, we are sure to satisfy all of your requirements. All welds are carefully performed to ensure they are continuous and crevice free.

    • -50°C to 250°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  11. RTD probe with process head and extension  RPL5-P

    RTD probe with process head and extension RPL5-P

    The lagging extension allows the terminal head to be mounted away from the process in order to protect any electronics housed within it or to allow the head to sit above any insulation. We can manufacture the sensor stem to your own diameter and length requirements and we have plenty of options available for the sensor and terminal head.

    • -50°C to 250°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  12. RTD probe with process head RPL4-P

    RTD probe with process head RPL4-P

    The sensor is useful where there are space constraints and where a lagging extension is impractical. We can manufacture the sensor stem to your own diameter and length requirements and we have plenty of options available for the sensor and terminal head.

    • -50°C to 250°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  13. RTD probe with RJT process connection RPL7-P

    RTD probe with RJT process connection RPL7-P

    We can manufacture the sensor stem in various diameters and lengths to meet your exact requirements and with various options available for the terminal head, including IP68 stainless steel versions, we are sure to satisfy all of your requirements. All welds are carefully performed to ensure they are continuous and crevice free.

    • -50°C to 250°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info
  14. RTD probe with Tri-Clamp process connection  RPL6-P

    RTD probe with Tri-Clamp process connection RPL6-P

    We can manufacture the sensor stem in various diameters and lengths to meet your exact requirements and with various options available for the terminal head, including IP68 stainless steel versions, we are sure to satisfy all of your requirements. All welds are carefully performed to ensure they are continuous and crevice free.

    • -50°C to 250°C operating temperature range
    • 2, 3 or 4 wire, Simplex or Duplex
    • Class A or B tolerance band
    • UKAS traceable calibration
    More Info

14 Item(s)

per page

Set Descending Direction